Recordum Airpointer®

Recordum Airpointer®

The Airpointer‘s modular design comprising a base unit, analyzing modules and sensor modules allows for a configuration according to different application requirements.

The Airpointer‘s compact design enables it to be installed almost everywhere. Due to its optimized thermal management, the airpointer consumes less power compared to conventional monitoring stations.

The airpointer offers a choice of analysis modules using type approved reference methods for monitoring airbornepollutants (SO2, NO2/NOX, CO, O3, and PM) classified as relevant by the EU, the WHO, the US-EPA and further responsible organizations all over the world.

A fast optical system or an approved PM analyzer is used for monitoring PM.

The integrated data management system records monitoring data of the airpointer‘s own analysis modules as well as various external third-party sensors. An internal web server enables data retrieval by using any Internet connection. Data are available worldwide via access authorisation and can be presented in clearly arranged graphics. All parameters can be displayed locally or online.

Category:

Description

Airpointer® – Air Quality Monitoring

The Airpointer‘s modular design comprising a base unit, analyzing modules and sensor modules allows for a configuration according to different application requirements.

The Airpointer‘s compact design enables it to be installed almost everywhere. Due to its optimized thermal management, the airpointer consumes less power compared to conventional monitoring stations.

The airpointer offers a choice of analysis modules using type approved reference methods for monitoring airbornepollutants (SO2, NO2/NOX, CO, O3, and PM) classified as relevant by the EU, the WHO, the US-EPA and further responsible organizations all over the world.

A fast optical system or an approved PM analyzer is used for monitoring PM.

The integrated data management system records monitoring data of the airpointer‘s own analysis modules as well as various external third-party sensors. An internal web server enables data retrieval by using any Internet connection. Data are available worldwide via access authorisation and can be presented in clearly arranged graphics. All parameters can be displayed locally or online.

 

Specifications

Airpointer 2D Airpointer 4D Airpointer +PM
2 of Pollutants Standard modules

Dimensions (H/W/D, w/o handle and sample inlets) 890/782/400 mm35/30.8/15.8 in.
Weight 65.8 kg/145.1 lbs
Power consumption* max. 670 W
Flow <2000ccm/min +2000 ccm/min for nephelometer

Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design

Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply

Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)

Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Pollutants Standard modules

Pollutant Weight
NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data
4 of Pollutants Standard modules

Dimensions (H/W/D, w/o handle and sample inlets) 1120/782/400 mm
44.1/30.8/15.8 in
Weight 73.9 kg/162.9 lbs
Power consumption* max. 670 W
Flow <3000ccm/min +2000ccm/min for nephelometer

Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design

Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply

Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)

Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Pollutants Standard modules

Pollutant Weight
NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data
2 of Pollutants Standard modules
Type approved PM10 or PM2.5 monitor (Thermo 5030 SHARP, Met One BAM1020)

Dimensions (H/W/D, w/o handle and sample inlets) 1200/782/615 mm
47.2/30.8/24.2 in.
Weight 110 kg/242.5 lbs
Power consumption* max. 1100 W
Flow  <2000ccm/min +16.7l/min for PM monitor

Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design

Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply

Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)

Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Pollutants Standard modules

Pollutant Weight
NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data